View and Download Kodak C180 user manual online. Kodak Digital Camera User Manual. C180 Digital Camera pdf manual download. Also for: C160, 8749400, Easyshare c160, Easyshare c180. Kodak easyshare c180 digital camera user manual. NOTE: For focus distances, see Camera Specifications starting on page 43. Using digital zoom Use digital zoom to get up to 5X magnification beyond optical zoom. Press Telephoto (T) until the slider is at the end of the optical zoom range. Release Telephoto (T), then press it again. NOTE: You may notice decreased image quality when using digital.
![Keithley 2420 Source Meter User Manual Keithley 2420 Source Meter User Manual](/uploads/1/2/5/0/125078044/251657374.jpg)
![Keithley source meter Keithley source meter](https://www.tek.com/sites/default/files/media/image/2400-graphical-sourcemeter-keithley_handle.jpg)
Keithley 2420 Source Meter Manual
Product overview The SourceMeter combines a precise, low-noise, highly stable DC Power supply with a low-noise, highly repeatable, high-impedance multimeter. It has 0.012% basic accuracy with 51⁄2-digit resolution. At 51⁄2 digits, the SourceMeter delivers 520 readings/second over the IEEE-488 bus. At 41⁄2 digits, it can read up to 2000 readings/second into its inter- nal buffer. The unit has broad source and measurement ranges: Model(2400: • Source voltage from 5μV to 210V; measure voltage from 1μV to 211V. • Source current from 50pA to 1.05A; measure current from 10pA to 1.055A. • Measure resistance from 100μΩ (<100μΩ in manual ohms) to 211MΩ. • Maximum source power is 22W. Model(2410: • Source voltage from 5μV to 1100V; measure voltage from 1μV to 1100V. • Source current from 50pA to 1.05A; measure current from 10pA to 1.055A. • Measure resistance from 100μΩ (<100μΩ in manual ohms) to 211MΩ. • Maximum source power is 22W. Model(2420: • Source voltage from 5μV to 63V; measure voltage from 1μV to 63.3V. • Source current from 500pA to 3.15A; measure current from 100pA to 3.165A. • Measure resistance from 10μΩ (<10μΩ in manual ohms) to 21.1MΩ. • Maximum source power is 66W. Models 2425 and(2430: • Source DC or pulse voltage from 5μV to 105V; measure voltage from 1μV to 105.5V. • Source DC current from 500pA to 3.15A; measure DC current from 100pA to 3.165A. • Source pulse current from 500pA to 10.5A; measure pulse current from 100pA to 10.55A. (Model 2430 only.) • Measure resistance from 10μΩ (<10μΩ in manual ohms) to 21.1MΩ. • Maximum DC source power is 110W. • Maximum pulse source power is 1.1kW. (Model 2430 only.) Model(2440: • Source voltage from 5μV to 42V; measure voltage from 1μV to 42V. • Source current from 500pA to 5.25A; measure current from 100pA to 5.25A. • Measure resistance from 10μΩ (<10μΩ in manual ohms) to 21.1MΩ. • Maximum source power is 66W. NOTESThe Models 24002410242024252430 and 2440 are Y2K compliant. Models with a “-C” suffix have the Contact Check option. See Appendix F. Some additional capabilities of the SourceMeter include: Concurrent measurements of all three functions over the remote Interface. Source-measure sweep capabilities (linear and logarithmic staircase sweeps, source sweep list of up to 2500 points, memory sweep of up to 100 instrument setups). 6-wire Ω measurement with programmable I-source or V-source with V or I clamp. 4-quadrant source and sink operation. Up to 12 stages of limit testing with a built-in comparator for pass/fail testing. Digital I/O for stand-alone binning operations or Interface to component handler. Programming language and remote interfaces — The SourceMeter uses the SCPI programming language and two remote Interface ports (IEEE-488/GPIB and RS-232C). Trigger-Link Interface to Keithley Series 7000 switching hardware. Math expressions — Five built-in, up to five user-defined (bus only). Reading and setup storage — Up to 2500 readings and seven setups (five user defaults, factory default, *RST default) can be stored and recalled. Closed-cover calibration — The instrument can be calibrated either from the front panel or remote Interface.
Keithley 2420 Source Meter
The Keithley 2420 60V/3A/60W SourceMeter SMU Instrument is designed specifically for test applications that demand tightly coupled sourcing and measurement. The 2420-C provides precision voltage and current sourcing as well as measurement capabilities; it is both a highly stable DC power source and a true instrument-grade 6 1/2-digit multimeter. Oct 08, 2009 I am now trying to write a program to remote control my Keithley 2420 source meter by using LabWindows/CVI 8.0. When I sent the commands into the source meter via GPIB interface, the source meter displays 'Error: 410' - Query Interrupted. It seems that I have sent a command to the instrument before reading the response to the first command. If a screw is present, connect it to safety earth grou nd using the wire recommended in the user documentation. The symbol on an instrument means caution, risk of danger. The user should refer to the operating instructions located in the user documentation in. Tektronix and Keithley. Fresenius dialysis machine 5008s user manual. Skip to content. Programming Manual for 2400 Source Meter. Models 2400, 2401, 2410, 2420, 2425, 2430, 2440, 6430. Tp-link wireless lite n router wr740n user manual. 3 posts. Page 1 of 1. Nmedelec Posts: 6. Here is the link to download the 2400 user manual: download.